The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
From the constant-speed variable-output motor driving test result of an interior permanent-magnet synchronous motor for a pump drive, we observed that there was an additional loss factor, which was not previously considered. Furthermore, a 3-D finite-element method analysis was performed to investigate the cause of the additional electromagnetic loss. Accordingly, it was confirmed that there was an...
This study confirmed that unexpected additional eddy current loss may occur in rotor's retaining plate, which is commonly applied to the Permanent Magnet Synchronous Motor(PMSM) rotor structure. In the study, it performs a comparison between the analysis value and the test value of the variable output PMSM motor's efficiency characteristic according to output power. In the process, it is inferred...