The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Frequency domain passivity theory is used to evaluate harmonic resonance instabilities in a system with multiple grid-tied voltage source converters (VSCs), and subsequently, a stabilizing controller using predictive current control (PCC) method is proposed to prevent such instabilities. The input admittance of VSCs using PCC can achieve passivity almost up to the Nyquist frequency. This research...
This paper presents an adaptive Zero-Voltage-Switching control (ZVS) method and a hybrid current control strategy for the GaN-based MHz Totem-pole PFC rectifier. This novel ZVS control achieves the minimum ZVS time margin and maximum switching frequency clamping by adaptively controlling the synchronous rectifier (SR) turn off current. This adaptive SR turn off current control is a unified control...