The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Perfectly balanced supply voltages are not possible in practice. Therefore, detection, discrimination and diagnosis of stator winding turn fault in the presence of unbalanced supply voltages for three-phase induction motors is needed. In this paper a novel approach is presented for stator winding turn incipient faults detection in the presence of different levels of voltage unbalance and at different...
Direct Torque Control (DTC) scheme uses the stator resistance of the machine for the estimation of stator flux. The variation of stator resistance, due to stator winding turn fault, creates an error in the estimated stator flux position that may subsequently cause a failure of the complete drive system. This paper proposes the possibility of developing a remedial operating strategy using artificial...
The paper presents closed-loop ac drive with 5-phase induction motor operating with voltage source inverter and sine-wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed control can be applied. In the presence of output filter both control and estimation algorithms should be modified...
It is documented that almost 98% of all voltage generated by electric utilities has up to 3% unbalance. Single phasing fault deserves special attention since phase loss is considered the worst case of unbalanced supply voltage. This paper focuses on unbalanced supply condition diagnosis and discrimination between an unbalance in the supply and phase loss fault. The discrimination will be based on...
This paper addresses the problem of rotor speed, flux and parameters estimation of induction motor on the basis of a three-order electrical model. Thus, we propose to use a particle filtering (PF) to estimate states and parameters for an induction motor. It is assumed that only the voltages stator currents are measurable. In addition, the rotor resistance and magnetizing inductance, which vary with...
A method for fault detection and diagnosis of stator inter-turn short circuits and unbalanced supply voltages for three phase induction machines is presented. The method is based on the analysis of the ratio of third harmonic to fundamental FFT magnitude component of the three-phase stator line current and supply voltage to detect different insulation failure percentages at different load conditions...