The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Thermal protection of firefighter protective clothing is greatly influenced by the air gap entrapped and moisture in clothing. In this paper, the effects of air gap size and position on thermal protective performance exposed to 84 kW/m2 heat source were investigated. Water was also added to thermal liner to understand the effect of air gap coupled with moisture on thermal protection. It was indicated...