The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The PWM current derivative technique for sensorless control of AC machines requires current derivative measurements under certain PWM vectors. This is often not possible under narrow PWM vectors due to high frequency (HF) oscillations which affect the current and current derivative responses. In previous work, researchers extended the time that PWM vectors were applied to the machine for to a threshold...
The Fundamental PWM technique for saliency tracking based sensorless (encoderless) motor control uses current derivative measurements to calculate the rotor position. However parasitic impedances in the drive, motor and cabling cause high frequency oscillations in the current, when the inverter's IGBTs switch. This prevents the immediate measurement of the current derivative when a new voltage is...