The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Grid-connected LCL-filtered inverters are commonly used for distributed power generators. The LCL resonance should be treated properly. Recently, many strategies have been used to damp the resonance, but the relationships between different damping strategies have not been thoroughly investigated. Thus, this study analyses the essential mechanisms of LCL-resonance damping and reviews state-of-the-art...
The impedance-based stability criterion is usually used to evaluate the performance of a current-controlled inverter in the weak grid with considerable grid impedance at the point of common coupling (PCC). The stability of the real inverter-grid system is the same as the virtual system where the ratio of the grid impedance and the inverter output impedance is the open-loop transfer function. However,...
For grid-connected inverters, the feedforward of the grid voltage at the point of common coupling (PCC) highly suppresses the grid current harmonics caused by the grid distortion; however, when the PCC grid is weak with non-negligible grid impedance, the feedforward of the PCC voltage arouses serious current harmonics or even instability. In order to maintain the stability in the weak grid case, the...
For grid-connected LCL-filtered inverters, recent applications often observe a weak grid at the point of common coupling (PCC) with non-negligible grid impedance. In this case, the previous control methods would perform poor or even cause the inverter protection. Especially when the feedforward of PCC voltage is designed to suppress grid current harmonics, phase and gain margins will be largely reduced...
For grid-connected LCL-filtered inverter, the inherent resonance of LCL filter endangers the stability so that the inverter is hard to be controlled. To solve the resonance, the capacitor-current-feedback active damping (AD) is welcomed. However, the digital control delay was not seriously considered in the previous studies. The research on the stability with such control considering the digital control...
Input characteristics of L-filtered pulse-width-modulation (PWM) converter with one-cycle-control (OCC) method was analyzed, and the contradiction between decreasing phase displacement angle and decreasing input current ripple was revealed when the maximum switching frequency was limited to ensure high system efficiency. Given this, LCL-filtering scheme was introduced and used on OCC PWM converter,...
The grid-connected LCL-filtered inverter is widely used in distributed power generation systems based on renewable energies. Single inverter-side current feedback control only needs to sample one current to realize both current control and inverter protection. However, with single inverter-side current feedback control, the closed-loop system is under-damped or even unstable due to the digital control...