The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The corrosion and ash deposition of low-temperature heating surface were investigated in a 660MW coal-fired power plant. The temperature-controlled test probes constructed of three materials were tested under different wall temperatures (90°C, 80°C, 70°C, 60°C, 50°C and 40°C). The metal specimens and deposit samples were analyzed by X-ray fluorescence, X-ray diffraction and scanning electron microscope...
The fouling characteristic of the flue gas cooler (FGC) in a large-scale coal-fired power plant was investigated by field sampling. Eleven deposit samples were taken from the FGC in a 660MW power plant. The elemental compositions, compound compositions and micro-morphologies of the samples were analyzed. The results showed that the fouling characteristic was different at the first stage and the second...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.