The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In large stage III lung tumors, planning delivery of doses exceeding 60 Gy can be challenging and time consuming. Intensity modulated radiation therapy (IMRT) can improve target coverage but may increase volumes receiving low-dose irradiation. We clinically implemented a novel hybrid IMRT (h-IMRT) technique that allowed plans to be produced quickly, and compared these plans with 4 other techniques...