The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents a single-phase grid-connected inverter with a power decoupling circuit which enables longer lifetime and high conversion efficiency. In the single-phase grid connected inverter, a power pulsation with twice the grid frequency is appeared in the input dc capacitors. In a conventional inverter, electrolytic capacitors with large capacitance have been used in order to reduce the large...
This paper presents a single-phase grid connected inverter with a power decoupling circuit. In the single-phase grid connected inverter, it is well known that a power pulsation with twice the grid frequency is contained in the input power. In a conventional inverter, electrolytic capacitors with large capacitance have been used in order to smooth the DC voltage. However, lifetime of those capacitors...
This paper presents a new method for power decoupling control of single phase AC/DC converters using three switch poles to achieve unity power factor operation at AC side and power decoupling function at DC side. The method proposed compensate the pulsating power at twice the grid frequency by absorbing low frequency ripple current to a DC decoupling capacitor through the third switch pole operation...
A photovoltaic AC module system has been expected to be installed on the private residences. The AC module inverter needs an active power decoupling circuit in order to enlarge the lifetime and to decrease the volume of the inverter by eliminating a large electrolytic capacitor on the input DC-bus. This paper proposes novel flyback-type single-phase grid interactive inverters with two modulation methods,...