The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper mainly introduces the design of the dummy load prototype, whose functions are to verify the capability of the International Thermonuclear Experimental Reactor magnetic power supply systems to operate at their rated power levels without energizing the superconducting coils. The rated inductance is 6.73 mH and the extreme pulse operation mode is 68 kA/15 s ON and 900 s OFF. Therefore, in...
This paper mainly introduces the research and development (R&D) of the dummy load prototype, whose functions are to verify the capability of the ITER magnetic power supply systems to operate at their rated power levels without energizing the superconducting coils. The rated inductance is 6.73 mH and the extreme pulse operation mode is 68 kA/15 s on and 900 s off. Therefore, in order to meet the...