The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In order to avoid the cavitation damage and the decrease of the energy dissipation of the stepped spillways with a large unit discharge, the air entrainments of the hydraulic jump aeration basin (HJAB) are theoretically and experimentally investigated for the hydraulic-jump-stepped spillway developed by the authors. It is shown that the submerged degree of the hydraulic jump and the air concentration...
The location of the inception point of the air entrainment directly affects the energy dissipation ratio, the cavitation damage control, and the training wall height designs for a stepped spillway and a stilling basin. In this paper, the boundary layer theory of plates is used to predict the location of the inception point of the air entrainment over the stepped spillways by assuming the steps on...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.