The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Experimental investigations on a small size solar chimney show that the rate of ventilation increases with increase of the ratio between height of absorber and gap between glass and absorber. This finding is in agreement with results of the steady-state mathematical model developed for analysis of such systems. Nine different combination of absorber height and air gap have been investigated on the...
The mathematical model for predicting airflow velocity in a solar chimney has been developed through predicting temperature of the absorber, air in flow channel and glass cover. Experimental validation of the model has been done using a solar chimney having less than a 1-m-high absorber. Investigations have been carried out with three different combinations of air gap and size of the inlet opening...