The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
As a promising alternative to centralized scheduling, sample-based scheduling is especially suitable for high fan-out workloads that contain a large number of interactive jobs. Compared to centralized schedulers, existing sample-based schedulers do not hold a global view of the cluster's resource status. Instead, the scheduling decisions are made solely based on the status of a small set of randomly...
Transit signal priority (TSP) is a cost-effective way to improve transit system punctuality and efficiency. Connected Vehicle environment can provide precise and detailed information on vehicle movements, which is essential for effective TSP operation. This paper presents an integrated control strategy of TSP and speed guidance under the environment of Connected Vehicles. The strategy targets on buses...
Sample based distributed scheduling methods have been shown to be promising lower overhead alternatives to their centralized counterparts. These methods can make fast decisions based on information gathered from just a small number of worker nodes instead of the whole cluster. Most recent works in the field tend to adopt a combination of probe actions and worker-end queues in their design. However,...
For high-power converters with low pulse ratios (e.g. 80 Hz load frequency with 600Hz carrier frequency for a 27 MVA Variable Frequency Drive), the current control loop design has been a challenge due to the large signal delay and potentially higher-order plant (LCL filter between the converter and machines). The stability issue and cross-coupling effect is a problem in such application. In this paper,...
In this paper, control strategies of a 22 MW / 27 MVA machine test bench using pumpback topology are introduced. The current loop design at extremely low pulse ratios (e.g. 600 Hz carrier frequency / 80 Hz load frequency) is developed. The system stability and dynamic response are analyzed. The challenges for high-power machine control with a sine filter and a transformer connected between the voltage-source-inverter...
In this paper, four current control strategies for voltage source PWM inverters with LCL-filter at extreme low pulse ratios (e.g. 80 Hz load frequency/600 Hz carrier frequency) are investigated. The system is a medium-voltage variable frequency drive (VFD) application with the power rating over 20 MW. The benefits and drawbacks of each scheme are summarized to provide a guideline for the current control...
This paper presents the investigation of damping concepts of the resonance oscillation of an LCL-filter in a PWM inverter as a variable-speed-drive with low pulse-ratio. The system is designed for general-purpose operation and should be connected to different machines working in mediumvoltage with a power of 22 MVA. Low current THD is required on the machine side, which makes the use of a filter necessary...