The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Hybrid Active Power Filters (HAPFs) can effectively suppress harmonic current in power-lines, the compensation precision of which rely heavily on the design of the current loop and dc voltage controllers. In this paper, the operation principle of a transformerless HAPF is introduced and analyzed, and then a double closed loop control strategy with power-line current feedback and the fifth harmonic...
The voltage-fed quasi-Z-source inverter (qZSI) has been presented advantageous for photovoltaic (PV) applications. This paper further develops the closed-loop controller for the qZSI operating in both stand-alone and grid-connected modes. Regarding to the limitation between the modulation index and shoot-through duty ratio, guideline of the reference selection for capacitor voltage to minimize the...