The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Pilot-scale simultaneous NOx and SOx removal from boiler emission was performed using an indirect-plasma and chemical hybrid process. The flue-gas flow rate was in the range of 450-1470 Nm3/h, the gas temperature was 280??C, the NOx concentration was 30 ppm for city-gas firing, and both NOx and SOx concentrations were 70 and 35 ppm for heavy-oil firing, respectively. Radical injection by an indirect...