The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
To mitigate subsynchronous control interaction (SSCI) in doubly fed induction generator (DFIG)‐based wind farm, this paper proposes a robust controller for rotor‐side converter (RSC) using fractional‐order sliding mode controller (FOSMC). The proposed FOSMC can improve robustness and convergence properties of the controlled system, thus achieving SSCI damping under various operating conditions. Impedance‐based...
This paper proposes a fractional‐order sliding mode control (FOSMC) based on feedback linearization (FL) technique to mitigate subsynchronous control interaction (SSCI) in doubly fed induction generator (DFIG)–based wind farms connected to series‐compensated transmission lines. A linearized form of the studied system is obtained with the use of FL, which leads to reduced system order and small computational...