The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Purpose
To propose and assess an improved method for calculating the equilibrium magnetization of arterial blood (
), used for calibration of perfusion estimates in arterial spin labeling.
Methods
Whereas standard
calculation is based on dividing a proton density–weighted image by an average brain–blood partition coefficient, the proposed method exploits partial‐volume data to adjust this...
Quantitative perfusion MRI based on arterial spin labeling (ASL) is hampered by partial volume effects (PVEs), arising due to voxel signal cross‐contamination between different compartments. To address this issue, several partial volume correction (PVC) methods have been presented. Most previous methods rely on segmentation of a high‐resolution T1‐weighted morphological image volume that is coregistered...