The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents the assessment of air flow in a multi-stage Axial Flux Permanent Magnet (AFPM) prototype which is set to operate at 100rpm. The CFD models are validated using experimental results to give a greater understanding of the air flow developed in the generator. The proposed ventilation design reduces the pressure loss at the entry resulting in a 10% reduction in maximum stator coil temperature...
This paper presents the thermal performance of NGenTec Axial Flux Permanent Magnet (AFPM) prototype generator operating at 100rpm through the thermal analysis on single stage. The CFD model coupled the heat transfer and fluid flow modelling provides good interpretation of the thermal behaviour of the test generator at steady state. In the comparison of two ventilation conditions, the CFD simulations...