The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
To improve the stability of the multistage centrifugal pump, a special test bench was built based on the Bently ADRE 408 portable vibration tester. Taking a cantilever multistage centrifugal pump as the research object, the axis orbit and the vibration spectrum of the pump were obtained at 0Qd (zero flow point), 1.0Qd (design flow point) and 1.5Qd (large flow point). Moreover, based on the Butterworth...
This paper proposes a method to optimize the design of a typical multistage centrifugal pump based on energy loss model and Computational Fluid Dynamics (ELM/CFD). Different grid numbers, turbulence models, convergence precisions, and surface roughness are calculated for a typical multistage centrifugal pump. External characteristic experiments are also conducted to benchmark the numerical simulation...