The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A single compressed and four-stage segregating auto-cascade refrigeration system was developed in this paper, the temperature of the liquid coolant in the tank with 5L could reach 150K. Cooling process after throttling was analyzed, and the effect of the different proportion of the refrigerants was also pointed out. Experimental results show that it takes nearly 4 hours and 12 minutes to realize the...