The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The measurement of power plant boiler drum water level has important significance. In this article, a new approach of estimating the position of steam-water with the image processing technology was proposed. Firstly the quality of images should be improved by using image preprocessing. Then the height of water level gauge should be determined according to the process of binary and edge extraction...