The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Failure of high pressure (HP) turbine blades in a low bypass turbofan engine is analyzed to determine its root cause. Forensic and metallurgical investigations are carried out on all the failed blades as well as the failed components of the downstream modules. Fatigue failure of one HP turbine blade at dovetail region is found to be the primary failure. This failure has caused extensive damages in...