The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
We discuss methods for full two-port vector network analyzer measurements in the 218-344- (using WR3) and 356-500-GHz (using WR2.2) frequency bands. Waveguide test sets (WR3 and WR2.2) utilize Oleson Microwave Laboratories Inc. frequency extenders with the Agilent 8510C network analyzer. On-wafer measurements in the 220-325-GHz band are demonstrated with GGB Industries Inc. coplanar-waveguide probes...