The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A control strategy for LCL Grid-connected voltage source converters is proposed. With only grid feedback current control, the proposal allows the use of the proportional plus resonant regulator (PR) optimal design, regardless of the filter resonant frequency. To prove its feasibility, the controller is simulated in a realistic system for different values of resonant frequency. In addition, its superiority...
In this paper, a current controller for an inverter connected to the grid through an LCL filter is proposed. Unlike classical active damping schemes, it is proposed to implement the controller by measuring the injected current only. It can be done irrespectively of the filter resonance frequency. In addition, it is possible to place the closed-loop poles of the system in an arbitrary way. The controller...