The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A fault-tolerant control method based on algebraic derivative estimation is introduced. It is applied on an electromagnetically supported plate as an example of a nonlinear and an open-loop unstable system. The design of the closed loop control is facilitated assuming that relevant faults are identified sufficiently precisely and fast. This is justified by a novel robust model-based fault identification...