The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The liquid entrainment process at the vertical up tee branch is widespread in mass and heat transfer applications. Existing liquid entrainment models mainly apply to T-junctions with small diameter ratios of branch to main line (d/D), which are unable to predict the liquid entrainment under large d/D conditions. The models of liquid entrainment onset and entrainment rate are developed under reasonable...