The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper describes the separation method between the primary side and secondary side, because the leakage current generated by the switching of the isolated AC/DC converter flows through the parasitic capacitance in the high frequency transformer In addition, the analysis method of the conducted noise on the basis of the leakage current by one-time converter switching is described. Furthermore,...
This paper describes the frequency analysis method of the conducted noise in AC/DC converter using SiC-MOSFET on the basis of the leakage current by switching. The error of the experimental and simulation result of the disturbance voltage is 10 dBμV. The simulation result can be closely simulated including resonance points. Furthermore, this paper presented verification results of designed EMI filters...