The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
We present a novel approach to detecting leaking reciprocating compressor valves based on the idea that a leaking valve affects the shape of the pressure-volume diagram (pV diagram). This effect can be observed when the valves are closed. To avoid disturbances due to the load control, we concentrate on the expansion phase, and linearize it using the logarithmic pV diagram. The gradient of the expansion...
This paper presents a novel approach to diagnosing faults in reciprocating compressor valves. Based on easily available vibration data, a transformation to a high-dimensional vector space is performed. By defining a metric in this vector space, the distance between the actual compressor state and a reference compressor state is calculated. Excessive distances indicate a faulty compressor. Since large...