The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper describes current state of the art of medical image processing and surgery support system. In it, typical medical image processing processes such as segmentation, registration and enhancement are described as an application of fuzzy logic. Second, orthopedic surgery and surgery support systems are introduced. In it, we meet the fuzzy logic application to ultrasonic system. Third, a bed-side...
Purpose Magnetic resonance imaging (MRI) is often used to detect and treat neonatal cerebral disorders. However, neonatal MR image interpretation is limited by intra- and inter-observer variability. To reduce such variability, a template-based computer-aided diagnosis system is being developed, and several methods for creating templates were evaluated. Method Spatial normalization for each individual’s...
Implanted knee kinematic analysis plays one of important role in clinical and research fields of total knee arthroplasty. Although there are some studies to analyze X-ray images for estimating 3-D knee kinematics, most of them cannot analyze dynamic video because they strongly depend on manual interaction of giving initial pose/position. This paper utilizes particle filter for analyzing dynamic radiograph...
This paper describes a trans-skull ultrasonic system that measures the blood flow velocity in brain under skull. In this system, we use an ultrasonic array probe with the center frequency of 1.0 MHz. The system determines the blood flow and locate blood vessel by Doppler effect. This Doppler effect is examined by the center of gravity shift in the frequency domain. We use three silicon tubes of different...
This paper describes a foot age estimation system using fuzzy logic. The method employs sole pressure distribution change data. The sole pressure data is acquired by a mat type load distribution sensor. The proposed method extracts step length, step center of sole pressure width, distance of single support period and time of double support period as gait features. The fuzzy degrees for young age,...
This paper proposes a body weight prediction method using autoregressive (AR) model and Fuzzy-AR model. First, we employ 6 persons body weight change data of 365 days. AR model predicts body weight of a day from these time-series data. We calculate an order of AR model for each person by Akaike's Information Criterion. In the experiment, we predicted body weight change of next day for those subjects...
This paper describes a testicular tubules evaluation using 1.0MHz ultrasonic array probe. In this system, we evaluate a diameter of testicular tubules. We employ an ultrasonic array probe with the center frequency of 1.0MHz. We employ evaluation index that cumulative relative frequency of amplitude values. In the experiment, we employ 24 nylon lines as the testicular tubules. Amplitude of large nylon...
Measurement of cerebral volume and surface area using magnetic resonance (MR) image is effective for quantitative diagnosis of cerebral diseases. The measurement should require a brain segmentation process. Although many approaches for adult brain have been studied, there are few studies for neonatal brain. This study proposes a brain segmentation method for neonatal brain. Based on system of systems...
It is important to improve the quality of marine radar images because marine radar systems play a principle role of sea surveillance. However, it is difficult to recover signal strength decay with increasing distance, signals of behind objects and of shaded area. This paper proposes a new approach to improve radar image quality with system of systems (SoS) technology. The SoS is based on a ship-to-ship...
This paper describes a personal verification method based on fuzzy logic using dynamic sole pressure distribution while walking. The method employs a pair id sole pressure distribution change, and it is acquired by a mat type load distribution sensor. As a preliminary experiment for shoes, we take sole pressure data by bare foot and two kind of slippered foot. We extract thirty nine gait features...
This paper describes a home care system for elderly by four detached multi-sensor network. The sensor network detects several bio-signals in bed. It consists of the following four sensors. An ultrasonic sensor detects human motion. An optical fiber sensor detects respiration. A mat-type sensor detects heart rate and respiration, and heart rate accesses autonomous nerve system. A microphone detects...
This paper describes a trans-skull ultrasonic system that measures the blood flow velocity through the brain's blood vessel under skull. In this system, we use an ultrasonic array probe with the center frequency of 1.0MHz. The system determines the blood flow by Doppler effect. This Doppler effect is examined by the center of gravity shift in the frequency domain. We test the system in the condition...
In this paper, we analyze human gait pattern and estimate her/his foot age. We acquire foot pressure distribution change as gait pattern by a mat type load distribution sensor. From the foot pressure distribution data, duration of gait cycle and center of foot pressure (CFP) changes are determined for each stride. We employ four estimation indexes such as step length, step CFP width, the time of double...
It is effective to evaluate magnetic resonance (MR) images for diagnosing neonatal cerebral disorders because they often accompany the deformation of the brain shape. However, there are many difficulties when radiologists manually extract cerebral surface from the MR images. Therefore, it requires to extract the cerebral surface from neonatal MR images automatically. There are many methods to extract...
Quantitative diagnosis of the knee joint dynamics is required to decrease the inner- and intra-observer variability. This paper proposes a noninvasive, unconstrained and free field of measurement system of 3 degree-of-freedom knee joint angles. The proposed system employs a compound sensor of inertial and magnetic sensors. Based on a rigid-body link model, the proposed method enables a measurement...
Automated morphometric analysis using human brain magnetic resonance (MR) images is an effective approach to investigate the morphological changes of the brain. However, even though many methods for adult brain have been studied, there are few studies for infantile brain. Same as the adult brain, it is effective to measure cerebral surface and for quantitative diagnosis of neonatal and infantile brain...
This paper describes a method for a heartbeat and respiratory rate monitoring system using air pressure sensors and ultrasonic oscillosensor. By using these sensors, we propose a detection method of the state of human and an extraction method of heartbeat and respiratory rate in bed by fuzzy logic. Our method was examined on four healthy volunteers. We successfully detected the state of human and...
This paper proposes a biometric personal authentication method based on one step foot pressure distribution change. We acquire the foot pressure distribution change by mat type load distribution sensor and use it as a personal authentication. We employ twelve features based on shape of footprint, and twenty seven features based on movement of weight while walking. A classifier for each feature is...
Brain shape is deformed regionally by kinds of cerebral diseases and the degree of progress. Therefore quantitative evaluation of the deformation using MR images is effective for diagnosis of cerebral diseases. We proposed a homologous brain shape modeling deformation for quantitative evaluation of the brain shape using sulcal-distribution index (SDI) in MR images. So in this paper, we propose the...
This paper describes a method for distribution of people monitoring system using a 3D camera. This camera measures distance and intensity distribution based on time of flight (TOF). From the obtained distance data, we perform clustering processing to detect the distribution of people. In our method, fuzzy logic plays a primary role to decide the cluster, i.e., people number. Our proposed method applied...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.