The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
With the increasing amount of data available from the harmonic monitoring systems in the distribution grid, it is becoming more important to evaluate the harmonic data. This paper presents an algorithm using data mining technique, in particular mixture modeling based on the Minimum Message Length (MML) method, to classify the harmonic data into clusters and identify useful patterns within the data...
One difficulty in calculating harmonic voltages and currents throughout a transmission or distribution system is the need for a precise model of the linear load, both in magnitude and composition, fed from each bus. It has become evident that the use of equivalents without a comprehensive check on the effects of all impedances actually present can lead to inaccurate estimation of the harmonic voltages...
An analysis of current transients caused by voltage notches in an industrial plant is presented in the paper. The source of current transients in the factory lighting was traced to the operation of the nearby six-pulse AC/DC converter. Because of the short duration of the phenomenon, it was not possible to determine if there is a parallel resonance using a standard power quality analyzer. To determine...
Residual current devices (RCDs) are most commonly used as a part of the protection system in low voltage installations. RCDs are supposed to disconnect the supply whenever the imbalance current between the live conductor(s) and the neutral conductor, i.e. residual current, exceeds the predetermined value. Such an imbalance is sometimes caused by current leakage through the body of a person who is...
An experimental investigation of diversity factors for CFLs (compact fluorescent lamps) in combination with LED (light emitting diode) lamps is presented in this paper. Diversity factors were calculated for different configurations of lamps connected to the same feeder in one phase. It was found that the presence of LED lamps with a high apparent power input can lead to considerable damping of harmonics...
Modern household customers use many power electronic based devices for their daily usage. Those devices emit harmonic current pollutions and eventually increase harmonic voltage distortion level in the network. In the future network, the background harmonic pollution in the MV and upstream networks could increase with the integration of more distributed generations. Thus, the harmonic related problem...