The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Simple and selective paper-based colorimetric sensors using silver nanoprism (AgNPrs) were conveniently fabricated and developed for the determination of chloride ions (Cl−) contaminated in the environment. Samples containing different concentrations of Cl− were analyzed. The analysis is based on the oxidative etching of the AgNPrs into smaller silver nanospheres (AgNPss) by Cl−. In the presence of...
A simple paper-based sensor with electrochemical detection was first developed for rapid, selective, and sensitive determination of acetylcholinesterase (AChE). The screen-printed graphene electrode was used as working electrode providing sensitivity for the sensor. The amperometric detection of AChE is based on the determination of thiocholine (TCh) produced from hydrolysis of acetylthiocholine chloride...
Carbofuran is a highly toxic pesticide that is heavily used in agriculture due to its high effectiveness and low cost. Improved methods that are simpler and lower cost are needed for carbofuran detection in food and agricultural samples. Herein, we describe the development of a unique electrochemical method for carbofuran-phenol, which is the main hydrolysis product of carbofuran. We have successfully...
A method for the determination of Ni(II) using ion-transfer to a hydroxide medium has been developed by the sequential injection-electrochemical analysis (SIECA), a combination between an automated flow-based analysis and electrochemical techniques with a homemade screen-printed carbon electrode (SPCE). A sample/standard solution was introduced into an electrochemical flow cell where the Ni(II) in...
Graphene is one of the promising hydrophobic carbon-based nanomaterials used for electrode modification in electrochemical sensor. However, hydrophobicity of graphene makes it incompatible with aqueous electrolyte solution, leading to significant impediment to the electron transfer process. Here, we aim to alter graphene property to be hydrophilicity by using an electrochemically reduced micellar...
A simple and highly sensitive electrochemical sensor based on an electrochemically reduced graphene oxide-modified screen-printed carbon electrode (ERGO-SPCE) for the simultaneous determination of sunset yellow (SY) and tartrazine (TZ) was proposed. An ERGO film was coated onto the electrode surface using a cyclic voltammetric method and then characterized by scanning electron microscopy (SEM). In...
A droplet-based electrochemical sensor for direct measurement of D-glucosamine was developed using carbon paste electrodes (CPEs) modified with gold nanoparticles (AuNPs) and polyaniline (PANI). Central composition design (CCD) was employed as a powerful method for optimization of parameters for electrode fabrication. The optimized amounts of AuNPs and PANI obtained from the response surface were...
Polyaniline/graphene quantum dots (PANI/GQDs) were used to modify a screen-printed carbon electrode (SPCE) in a flow-based system. A method for rapidly determining the Cr(VI) concentrations by using stopped-flow analysis has been developed using an Auto-Pret system coupled with linear-sweep voltammetry using the PANI/GQD-modified SPCE. The GQDs, synthesized in a botton-up manner from citric acid,...
A nanocomposite of graphene (G), polyvinylpyrrolidone (PVP) and polyaniline (PANI) modified onto screen-printed carbon electrode (SPCE) using an electrospraying technique was developed for simultaneous determination of five parabens in beverages and cosmetic products by high performance liquid chromatography. PVP and PANI were used as the dispersing agents of graphene, and also for the enhancement...
A development of ultra-high performance liquid chromatographic coupled with a novel inkjet-printed conductive ink-modified electrode for a fast and simultaneous determination of polyphenolic antioxidants was achieved. Two printing techniques were selected for fabrication and modification including (i) an in-house screen-printing method and (ii) an inkjet-printing method, respectively. A conductive...
Flow injection amperometric (FI-Amp) sensor was developed for sensitive and selective determination of hydroquinone. A simple screen printed carbon electrode (SPCE) was modified with various nanomaterials for improvement of sensitivity on the determination of quinone. As a result, the appropriate sensitivity is obtained from the SPCE modified with carbon nanotube (CNT) which indicated that CNT contributed...
Electrochemical detection provides a simple, rapid, sensitive and inexpensive method for DNA detection. In traditional electrochemical DNA biosensors, the probe is immobilized onto the electrode. Hybridization with the DNA target causes a change in electrochemical signal, either from the intrinsic signal of the probe/target or through a label or a redox indicator. The major drawback of this approach...
Various metal nanoparticles (NPs) decorated on carbon nanotube (CNT) was modified on the home-made screen printed carbon electrode (SPCE) in order to enhances sensitivity of hydrogen peroxide (H2O2) determination. The simple casting method was used for the electrode modification. The monometallic and bimetallic NPs modified electrodes were investigated for their electrochemical properties for H2O2...
Creatinine is one of many markers used to investigate kidney function. This paper describes a low-cost enzymatic paper-based analytical device (enz-PAD) for determining urine creatinine. The disposable dead volumes of creatinine enzyme reagents from an automatic analyser cassette were utilised. Whatman No. 3 paper was cut into long rectangular shapes (4×40mm2) on which the enzyme reagents, R1 and...
For the first time, gold nanoparticles (AuNPs) modified screen-printed carbon electrode (SPCE) was developed as working electrode in ultra-high performance liquid chromatography (UHPLC) coupled with electrochemical detection (UHPLC-ED) for simultaneous determination of thiram, disulfiram, and N,N-diethyl-N’,N’-dimethylthiuram disulfide, their derivative compound. The separation was performed in reversed-phase...
Highly sensitive colorimetric detection for Pb 2+ has been developed using maleic acid (MA) functionalized GNP. The –COOH on MA was used to modify GNP surface whereas the other –COOH functional group have strong affinity to coordination behavior of Pb 2+ allowing the selective formation more than other ions. MA–GNPs solution changed from red to blue color after the addition of Pb ...
A novel colorimetric assay based on silver nanoplates (AgNPls) for detecting nickel ions (Ni 2+ ) has been developed. Glutathione (GSH) and l-cysteine (Cys) were used to modify the AgNPls surface, exhibiting extremely high selectivity towards Ni 2+ over other metal ions under specific conditions. Upon addition of Ni 2+ to the modified AgNPls solution, a distinctive color change...
An ultra-performance liquid chromatography (UPLC) coupled with graphene/polyaniline (G/PANI)-modified screen-printed carbon electrode was developed for separation and sensitive determination of eight sulfonamides (SAs) in shrimp. Electrospraying was selected for electrode modification because it can generate the well dispersion of G/PANI nanocomposites on the electrode surface. Prior to electrochemical...
An automated method has been developed for determining the concentration of inorganic arsenic. The technique uses sequential injection/anodic stripping voltammetry with a long-lasting gold-modified screen-printed carbon electrode. The long-lasting gold electrode was electrochemically deposited onto a screen-printed carbon electrode at a potential of −0.5V vs. Ag/AgCl in a supporting electrolyte solution...
A spraying method with lacquer was developed for the fabrication of paper-based devices. A patterned iron mask was initially placed on a filter paper and held tightly attached by a magnetic plate placed on the opposite side. After that, acrylic lacquer was sprayed on the filter paper to create a hydrophobic area while the hydrophilic area was protected with the iron mask. The optimal conditions for...