The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The onset of nucleate boiling in the flow of water through a microchannel heat sink was investigated. The microchannels considered were 275μm wide by 636μm deep. Onset of nucleate boiling was identified with a high-speed imaging system and the heat flux at incipience was measured under various flow conditions. An analytical model was developed to predict the incipient heat flux as well as the bubble...