The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The conducted EMI disturbs the sensitivity device in current mode finally. This paper proposed a new common mode current suppression method after the transfer path of common mode current is analyzed in motor system. The proposed method is that the metal shielding layer with high conductivity is placed between power electronic device and heat sink. The electric field transfer is cut and the parasitical...