The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Steel coupons were buried in soil for 2months under cathodic protection. Their residual corrosion rates were deduced from voltammetry and weight loss measurements. In aerated soils, the current density due to O 2 reduction, j K,O2 , was modelled with a mixed activation–diffusion controlled kinetic. The anodic part j A of the current density j, computed as j A =j−j ...
Steel coupons were buried in soil boxes for 2.5months, with or without cathodic protection. A soil from the field was used and moistened by demineralized water or 5gL −1 Na 2 SO 4 solution. Instantaneous corrosion rates were deduced from voltammetry experiments while average values were obtained by weight loss measurements. A detailed analysis of the polarization curves led...