The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper reports the effects of Co 2+ contamination on PEM fuel cell performance as a function of Co 2+ concentration and operating temperature. A significant drop in fuel cell voltage occurred when Co 2+ was injected into the cathode air stream, and Co 2+ contamination became more severe with decreasing temperature. To investigate in detail the mechanism of Co ...
The oxygen reduction reaction (ORR) catalyzed by Pt was studied in the presence of Co 2+ using cyclic voltammetry (CV), rotating disk electrode (RDE), and rotating ring-disk electrode (RRDE) techniques in an effort to understand fuel cell cathode contamination caused by Co 2+ . Findings indicated that Co 2+ could weakly adsorb on the Pt surface, resulting in a slight change...