The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Ten full-scale field tests were conducted to study the performance of basalt fiber reinforced polymer (BFRP) strip strengthened autoclaved aerated concrete (AAC) masonry walls subjected to vented gas explosions. Three walls i.e. unstrengthened, rear-face strengthened and front-face strengthened wall specimens were prepared for blast tests. The testing data including overpressure time histories of...
A total of nine full-scale in-situ tests were carried out to investigate the performances of autoclaved aerated concrete (AAC) masonry walls subjected to vented gas explosions. The testing data including overpressure time histories of vented gas explosions, displacement time histories, and damage characteristics of AAC masonry walls in each test were recorded and analysed. It was found that the responses...