The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The subject of the research was a material in the form of a ϕ38×4 pipe from HCM12 steel used for steam superheater coils in power boilers with supercritical and ultra-supercritical steam parameters. This article presents results of investigations of mechanical properties and microstructure of material of the examined tube in the as-received condition and after 100,000 h service at 585°C under creep...