The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The effect of continuously dosing membrane bioreactors (MBRs) with ferric chloride (Fe(III)) and ferrous sulphate (Fe(II)) on phosphorus (P) removal and membrane fouling is investigated here. Influent phosphorus concentrations of 10 mg/L were consistently reduced to effluent concentrations of less than 0.02 mg/L and 0.03–0.04 mg/L when an Fe(III)/P molar ratio of 4.0 and Fe/P molar ratio (for both...
A pilot scale membrane bioreactor (3.7 m3/day capacity), configured for alternate point ferrous sulphate addition, was evaluated in a fourteen month trial to comply with an effluent discharge requirement of less than 0.15 mg-P/L at the 50th percentile and less than 0.30 mg-P/L at the 90th percentile. Ferrous sulphate was added at a molar ratio (Fe(II):PO4) of 2.99 in the filtration chamber for 85...