The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Component minimized multi-machine drives have recently become an area of much research interest. One such drive comprises two three-phase induction motors supplied by a five-leg voltage source inverter (VSI). With only five legs available to supply two three-phase motors one inverter leg is connected to both motors and the drive is controlled in such a way that both machines can operate independently...
Component minimized multi-machine drives have recently become an area of much research interest. One such drive comprises two three-phase induction motors supplied by a five-leg voltage source inverter. With only five legs available to supply two three-phase motors one inverter leg is connected to both motors and the drive is controlled in such a way that both machines can operate independently. Many...
Industrial applications often require a number of variable speed electric drives. In the majority of cases, these multi-motor drive systems require independent control of individual motors. Over the past decade, research efforts have been made to reduce the number of power electronic devices required in multi-motor drive systems in order to reduce the overall complexity and hence cost of the drive...
Recent research has shown that it is possible to independently control two three-phase induction machines while supplying them via a single five-leg voltage source inverter (VSI). In such a two-motor drive system one phase of each motor is connected to a common inverter leg. Major shortcoming of this topology for general-purpose applications is the need to double the DC bus voltage in order to achieve...