The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
We examine array configuration and silicon-lens integration of asymmetric-dual-grating-gate high-electron-mobility transistors (A-DGG HEMTs) as plasmonic terahertz detectors in order to enhance their external coupling efficiencies. We demonstrate 4-fold enhancement of the efficiency by an array of four series-connected detectors and 6-fold enhancement by the hyper-hemispherical silicon-lens integration...
We experimentally verify that the low external responsivity of nanostructured asymmetric-dual-grating-gate high-electron-mobility transistors (A-DGG HEMTs) as plasmonic terahertz detectors developed so far is attributed to their low external coupling efficiency. We separately demonstrate (1) 4-fold enhancement of the efficiency by an array of series-connected 4×1 detectors due to the increase in the...
A terahertz imaging system operating at 0.3 THz has been developed for the purpose of detecting foreign substances in foods conveyed at a velocity of higher than 20 m/min. The imaging system has two Schottky barrier diode arrays which detect horizontally and vertically polarized terahertz waves independently and simultaneously. Experiments have shown that the imaging system can successfully obtain...
Permanent magnet quadrupoles (PMQ) and sextupoles (PMSx) have been fabricated and tested. Their effective strengths are variable. The PMQ has been developed as a final focus magnet for a linear collider. There is enough space to put Gluckstern's 5-ring singlet structures in each incoming beam line. The magnetic center offsets and higher harmonic components can be adjusted by adjusting the positions...