The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Background
In this study, we evaluate a new flexible, single‐arm robotic system in performing thyroidectomy via a retroauricular approach.
Methods
Four fresh cadavers were used. Technical details of the new system are discussed, and the comprehensive surgical procedures are described step by step.
Results
This single‐port flexible system could be used to successfully perform retroauricular thyroidectomy...
Objective
Previously, we have reported the feasibility of retroauricular (RA) robotic thyroidectomy. Despite its promising surgical outcomes, there were certain intrinsic mechanical limitations inherent to the da Vinci Si System (Intuitive Surgical, Sunnyvale, California, U.S.A.). Since the advent of an upgraded model, the Xi System (Intuitive Surgical), we have actively incorporated the new model...