The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A performance‐based safety factor durability design format is proposed and developed with respect to carbonation of concrete. Deemed‐to‐satisfy rules based on a partial safety factor design approach are developed for the carbonation of concrete. This design format follows the design procedure proposed in EN 1990 [1]. For the design format, the limit state equation for the carbonation is introduced...
The paper reports on a benchmark of European deemed‐to‐satisfy rules for exposure class XC (carbonation exposed structural members). The benchmark of the descriptive rules was carried out following the probabilistic design approach for carbonation‐induced corrosion developed in [1] and adopted in fib bulletin 34: Model Code for Service Life Design (2006) [2] and fib Model Code for Concrete Structures...