The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Fatigue tests on wet steam generator 20G tubes were carried out and the metal magnetic memory (MMM) signals were detected. Though the analysis of MMM signals from different fatigue cycles, the variation characteristic of the MMM signals was obtained and a novel quantitative evaluation method of the early failure by MMM technology was proposed and applied in oilfield on-site test finally. The test...