The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Ghosting flame phenomena and the corresponding fire dynamics in a corner ceiling vented cabin were experimentally studied. Various parameters including fuel mass loss rate (MLR), gas and fuel temperature as well as local oxygen concentration were measured in the experiments. Ghosting flame was observed when the fuel MLR increased to its maximum value and the oxygen concentration dropped to extremely...
A series of experiments were conducted in a ceiling vented compartment to obtain the horizontal opening effect on pool fire behavior. Three pan diameters and six horizontal opening sizes were adopted and measurements included the mass loss, oxygen concentration and temperature in the horizontal opening. A dimensionless horizontal ventilation parameter coupling horizontal opening and pool fire areas...