The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
To establish a series of ppm-level high-voltage ratio standards up to 110 kV, we propose and have designed low-voltage-excitation two-stage voltage transformers (LVE-TSVTs) for high voltage. Ratio traceability for a 10 kV/100 V LVE-TSVT is vital in this scheme. This paper focuses on the voltage ratio traceability of the 10 kV LVE-TSVT by measuring the errors of the reference voltage and the voltage...
This paper describes the principle, structure and the self-calibration method of a new type of current comparator which is designed and constructed by NIM. This current comparator is based on “shield guiding structure”, and its ratio is from 0.1∶1 to 1∶1.
This paper introduces a calibration method for measuring the Miniature Current Transformer (MCT) which is based on sampling technology. In this way, we can measure the miniature current transformer with secondary current from 1mA to 100mA and different load accurately.
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.