The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents a novel control strategy to achieve unity power factor with an energy management system (EMS) in an AC microgrid. The digitally controlled, power electronics based EMS controls the microgrid in both grid-connected and islanding mode by making sure that energy is harvested from distributed resources, stored in batteries, and available at all times for critical loads. In this paper...
This paper presents the benefits of transitioning from traditional generator employment in a Forward Operating Base (FOB) to an alternative architecture using a power electronics based Energy Management System (EMS). The EMS provides an interface between power sources, loads, and energy storage elements to form a microgrid. Using power electronics and programmable logic, the EMS enables more efficient...