The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A discrete-time predictive current controller, for the application of active power filtering, is designed and analyzed in this paper. A modified algorithm of reference current prediction in the conditions of step change in amplitude and/or frequency is proposed. The theoretical analysis and the validity of the proposed method are verified by simulations. Comparison for the 5th and the 7th harmonic...
This paper proposes an accurate and simple current control for shunt active filters (SAF) based on a P+Resonant compensator used in conjunction with traditional PI control. The proposed current control system is designed to operate with a single dq reference frame, synchronous with the 50 Hz supply voltage, for the compensation of 5th and 7th harmonics. Another major advantage of this strategy is...
This paper presents a new method to balance the DC link voltages in a 3 level diode clamped rectifier, even in the presence of unbalanced loads which cause a non-zero neutral point current. The method employs an offset which is added to each of the inverter modulation waves. This offset causes a zero sequence voltage which can drive the desired neutral point current whilst maintaining balanced DC...
This paper discusses the application of a shunt active power filter with energy storage, for voltage and power improvements within a local power supply network (micro-grid) in presence of distributed generation. Theoretical analysis investigates the control the shunt active power filter in response to voltage sag. The shunt active filter operates over a short period of time, and is coordinated with...
This paper presents a new method to balance the DC link voltages in a 3 level Diode Clamped Rectifier, even in the presence of unbalanced loads which cause a non-zero neutral point current. The method employs an offset which is added to each of the inverter modulation waves. This offset causes a zero sequence voltage which can drive the desired neutral point current whilst maintaining balanced DC...