The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Real-time sampling and feedback can effectively reduce the sampling delay and improve the robustness of the active damping control for grid-connected LCL-filtered inverter. However, the practicability of this approach would be limited by the aliasing problem of sampling. In order to solve the aliasing problem, a systematic analysis is done to figure out the relation between the sampling instant of...
The grid-connected LCL-filtered inverter is widely used in distributed power generation systems based on renewable energies. Single inverter-side current feedback control only needs to sample one current to realize both current control and inverter protection. However, with single inverter-side current feedback control, the closed-loop system is under-damped or even unstable due to the digital control...
An -type filter is widely used in the grid-connected inverter. However, with only injected grid current control, the current harmonics and low bandwidth caused by the resonance peak cannot be tolerated. The active damping (AD) method with an extra feedback provides a high rejection of the resonance so that the dynamic is improved; however, the high-precision sensing circuit for the extra feedback...
The under-damped resonance in the grid-tied LCL-filtered inverter yields much difficulty in designing the controller. One interesting solution is that if the weighted average of currents through two inductors is fed back, the close-loop control based on the feedback of the weighted current is easily designed to maintain satisfactory dynamic. However, it has been proved that under-damped conjugate...
LCL filter characterized with high harmonic current attenuating performance and low cost are suitable for medium and high power grid-connected inverters. But, the resonance poles endanger the safety of operation, and the active damping (AD) is an effective means to increase the system security. This paper focus on the theoretical exercise of possible strategies to damp the resonance of grid-connected...
Grid connected inverter can attenuate high frequency harmonics effectively through an LCL filter which has potential benefits for the inverter to get higher harmonic performance with lower switching frequency and less inductance in contrast with L filter. However, LCL filter is a third order system without damping and easy to resonate. In order to eliminate resonance and improve the system stability,...