The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Power quality is a key issue in island, shipboard integrated electric power systems (IEPS). However, it is not of easy accomplishment, due to the complexity of shipboard power station (generators are many and differ by sizes, prime movers, control systems, etc.) and to the intrinsic weakness of the shipboard grid. This paper presents a new approach for controlling voltage and reactive power generated...
All electric ship alternators are connected to a main busbar which feeds all shipboard electric loads. To fulfill power quality requirements of the resulting electrical system, high-performance control of busbar voltage and frequency is needed. Such a task is not of easy accomplishment, due to the complexity of shipboard power station (generators are many and differ by sizes, prime movers, control...