The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Voltage island has become a very effective design style for power saving in low-power design. However, the new design style also brings forward new challenges, especially to the designers of power/ground (P/G) networks. In this paper, we study the power delivery problem in voltage island designs, and propose to consider voltage drop during the floorplanning process to reduce design iterations. Our...